KCL-03RL/BP
ECOZ
ECOZ inverter heat pumps can be used for many purposes in a building. It can be directly connected to various terminals, including a fan coil, radiator, floor heating, etc., and it is more flexible to use. Apart from heating and cooling, ECOZ inverter heat pump can also be connected to the hot water system in the building, realizing the integration of 24-hour hot water, cooling in summer, and heating in winter.
ECOZ inverter heat pumps can be used for many purposes in a building. It can be directly connected to various terminals, including a fan coil, radiator, floor heating, etc., and it is more flexible to use. Apart from heating and cooling, ECOZ inverter heat pump can also be connected to the hot water system in the building, realizing the integration of 24-hour hot water, cooling in summer, and heating in winter.
ECOZ Inverter Heat Pump (cooling+heating combined supply) | ||||
Model | KCL-03RL/BP | KCL-06RL/BP | ||
Refrigeration capacity (kW) | 7.8 | 16 | ||
Heating capacity (kW) | 10.5 | 22 | ||
Rated input power (kW) | 2.64 | 5.63 | ||
COP | 3.98 | 3.99 | ||
Voltage | 220V/1ph/50Hz | 380V/3ph/50Hz | ||
Current rating (A) | 12.3 | 9.5 | ||
Rate of hot water production (L/H) | 210 | 440 | ||
Coverable floor heating area (㎡) | 75 | 155 | ||
Output water temperature (℃) | ≦65 | ≦65 | ||
External fan air volume (m³/H) | 3000 | 6000 | ||
External fan power (w) | 90 | 180 | ||
Number of compressors | 1 | 1 | ||
Water-side heat exchanger | High-efficiency tank heat exchanger | |||
Water flow rate (m³/H) | 3 | 6 | ||
Water resistance loss | 5kpa | 5kpa | ||
Refrigerant | R410A | R410A | ||
Working temperature | -30℃~45℃ | -30℃~45℃ | ||
Mainframe Dimension | 1115*725*710 | 1030*40*1335 | ||
Inlet and outlet pipe diameter | DN25 | DN25 | ||
Weight (KG) | 65 | 110 |
ECOZ Inverter Heat Pump (cooling+heating combined supply) | ||||
Model | KCL-03RL/BP | KCL-06RL/BP | ||
Refrigeration capacity (kW) | 7.8 | 16 | ||
Heating capacity (kW) | 10.5 | 22 | ||
Rated input power (kW) | 2.64 | 5.63 | ||
COP | 3.98 | 3.99 | ||
Voltage | 220V/1ph/50Hz | 380V/3ph/50Hz | ||
Current rating (A) | 12.3 | 9.5 | ||
Rate of hot water production (L/H) | 210 | 440 | ||
Coverable floor heating area (㎡) | 75 | 155 | ||
Output water temperature (℃) | ≦65 | ≦65 | ||
External fan air volume (m³/H) | 3000 | 6000 | ||
External fan power (w) | 90 | 180 | ||
Number of compressors | 1 | 1 | ||
Water-side heat exchanger | High-efficiency tank heat exchanger | |||
Water flow rate (m³/H) | 3 | 6 | ||
Water resistance loss | 5kpa | 5kpa | ||
Refrigerant | R410A | R410A | ||
Working temperature | -30℃~45℃ | -30℃~45℃ | ||
Mainframe Dimension | 1115*725*710 | 1030*40*1335 | ||
Inlet and outlet pipe diameter | DN25 | DN25 | ||
Weight (KG) | 65 | 110 |