Availability: | |
---|---|
Quantity: | |
KCR-50R
ECOZ
ECOZ air can give you more comfortable warmth
The use of advanced air energy heat pump technology, energy saving 75% than ordinary water heaters to produce the same hot water, more energy saving than ordinary electric water heaters, the annual average energy efficiency ratio is several times that of electric heating, high energy efficiency.
Commercial Heat Pump Water Heater
ECOZ Heat Pump Water Heater produce domestic hot water centrally and then deliver it to users through hot water pipeline, which can provide all-weather hot water supply for factories, schools, hospitals, hotels and other large buildings.
Heat pump water heater uses air and water energy as heat source, through compressor compression, the refrigerant absorbs heat into high temperature and high pr
essure gas in
the evaporator, and absorbs a large amount of heat after throttling by expansion valve, then enters into the condenser after increasing condensation pressure, and then drains heat into water through water pump, thus completing a cycle.Beauty shop
Bath water temperature 50℃, 150-200 liters/person, to fill a number of wooden buckets of hot water in a short time.
Fitness center
The cooling water temperature is 42℃, 30-50 liters/person, to use water at the same time, the water pressure is good, the water temperature is stable, and the hot water is continuously supplied.
The baby swimming pool
Swimming water temperature 38℃, 150-200 liters/person, large water consumption, to fill a number of baby swimming pool hot water in a short time.
Collective dormitory centralized water supply
Water temperature 42℃, 30-50 liters/person. To use water at the same time, the water pressure is good, the water temperature is stable, and the hot water is continuously supplied.
Connections
The air source heat pump water heater consists of a main unit (i.e. compressor) and an auxiliary heating device, of which the main unit and the auxiliary heating device adopt the inverse Carnot principle, after which the hot water is stored in an insulated tank, and the hot water is delivered to the room through the hot water pipeline when the user uses it.
The unit runs stably and adopts multiple noise reduction technologies, so there is basically no noise generated when the unit is running.
1. High water temperature: water outlet temperature can reach up to 65°C.
2. Adopts indirect heating method, separates water and electricity, has no leakage risk, eliminates potential safety hazards, and can be used in all seasons.
3. Use R410A environmental protection refrigerant .
4. Intelligent detection of defrost, pipeline anti-freeze function.
5.Stable performance, not affected by the external environment. It can be operated all year round without being affected by bad weather such as night, cloudy days, rain and snow, and can supply hot water 24 hours a day, 365 days a year
ECOZ air can give you more comfortable warmth
The use of advanced air energy heat pump technology, energy saving 75% than ordinary water heaters to produce the same hot water, more energy saving than ordinary electric water heaters, the annual average energy efficiency ratio is several times that of electric heating, high energy efficiency.
Commercial Heat Pump Water Heater
ECOZ Heat Pump Water Heater produce domestic hot water centrally and then deliver it to users through hot water pipeline, which can provide all-weather hot water supply for factories, schools, hospitals, hotels and other large buildings.
Heat pump water heater uses air and water energy as heat source, through compressor compression, the refrigerant absorbs heat into high temperature and high pr
essure gas in
the evaporator, and absorbs a large amount of heat after throttling by expansion valve, then enters into the condenser after increasing condensation pressure, and then drains heat into water through water pump, thus completing a cycle.Beauty shop
Bath water temperature 50℃, 150-200 liters/person, to fill a number of wooden buckets of hot water in a short time.
Fitness center
The cooling water temperature is 42℃, 30-50 liters/person, to use water at the same time, the water pressure is good, the water temperature is stable, and the hot water is continuously supplied.
The baby swimming pool
Swimming water temperature 38℃, 150-200 liters/person, large water consumption, to fill a number of baby swimming pool hot water in a short time.
Collective dormitory centralized water supply
Water temperature 42℃, 30-50 liters/person. To use water at the same time, the water pressure is good, the water temperature is stable, and the hot water is continuously supplied.
Connections
The air source heat pump water heater consists of a main unit (i.e. compressor) and an auxiliary heating device, of which the main unit and the auxiliary heating device adopt the inverse Carnot principle, after which the hot water is stored in an insulated tank, and the hot water is delivered to the room through the hot water pipeline when the user uses it.
The unit runs stably and adopts multiple noise reduction technologies, so there is basically no noise generated when the unit is running.
1. High water temperature: water outlet temperature can reach up to 65°C.
2. Adopts indirect heating method, separates water and electricity, has no leakage risk, eliminates potential safety hazards, and can be used in all seasons.
3. Use R410A environmental protection refrigerant .
4. Intelligent detection of defrost, pipeline anti-freeze function.
5.Stable performance, not affected by the external environment. It can be operated all year round without being affected by bad weather such as night, cloudy days, rain and snow, and can supply hot water 24 hours a day, 365 days a year