cn_ecoz@163.com   +86-18924287993 / +86-13922412592 / +86-20-86786386
You are here: Home » Products » Heating Heat Pump » ECOZ Auxiliary home split Heating Heat Pump

Product Category

ECOZ Auxiliary home split Heating Heat Pump

Heating + cooling double jet enthalpy double jet enthalpy technology
Improve the energy efficiency of heating and cooling to achieve energy saving.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button
  • KCL-10RL

  • ECOZ


ECOZ Heat Pump

Guangzhou Yike New Energy Technology Co., Ltd. was founded in 2011, is a research and development, independent innovation, production, sales as one of the modern science and technology enterprises, has been committed to manufacturing and sales of heat pump drying dehumidifier, central air conditioning, heat pump water heater and other products.


Through years of research and development and practical experience, the core products of heat pump drying dehumidifier have formed five series of heat pump drying dehumidifier: (1) wood drying special heat pump drying dehumidifier. (2), agricultural products special heat pump drying dehumidifier. (3) Seafood, fish special heat pump drying dehumidifier. (4) Special heat pump drying and dehumidifying machine for production line. (5) Chinese herbal medicine special heat pump drying dehumidifier. The products are sold all over the country and are well received by new and old customers at home and abroad.



采暖热泵

The use of advanced air energy heat pump technology, energy saving 75% than ordinary water heaters 6 to produce the same hot water, more energy saving than ordinary electric water heaters, the annual average energy efficiency ratio is several times that of electric heating, high energy efficiency.

Variable frequency compressor is efficient, energy saving, stable and durable. The air conditioner uses a frequency conversion compressor and matches an outdoor fan to build DC frequency conversion technology. Compared with ordinary fixed frequency air conditioners, it has the technical advantages of quieter, more energy saving and more stable. The use of air jet enthalpy compressor, low temperature operation performance is better.

The air source heat pump uses advanced noise reduction technology, double shock absorption structure, high-quality shock absorption pad, wind blade noise reduction technology, and the compressor and other important parts are wrapped with anti-noise materials to achieve sound-sound-buffer triple noise reduction technology, greatly reducing the noise emitted during operation.

ECOZ heating heat pump can be used for many purposes in a building. It can be directly connected to various terminals, including fan coil, radiator, floor heating, etc., and it is more flexible to use with it. Apart from heating and cooling, ECOZ heat pump can also be connected to the hot water system in the building, realizing the integration of 24-hour hot water, cooling in summer and heating in winter.


ECOZ Product advantages


R410A制冷剂


Air source heat pump is a kind of energy-saving device that can make the heat flow from the low heat source air to the high heat source. It is a form of heat pump. As the name suggests, the heat pump is like a pump, which can convert the low heat energy that can not be directly used into the high heat energy that can be used, so as to achieve the purpose of saving part of the high energy.


1. The unit is equipped with intelligent defrost function and intelligent induction automatic defrosting, which effectively solves the situation that the unit cannot start due to cold frosting.


2. The use of high-quality spare parts effectively reduces the probability of frost formation and ensures the smooth operation of the unit in cold environments.


3. Microcomputer automatic control,double automatic control, automatic circulation heating, not subject to weather conditions, can run every day all year round, no need for personal care.


4. Using environmentally friendly refrigerant, driven by only a small amount of electrical energy, low energy consumption, no pollutant emissions during the operation of the heat pump unit.


5. Intelligent low temperature heat pump to achieve cold winter heating is not limited by low temperature building durable, long life.


6. Heating + cooling double jet enthalpy double jet enthalpy technology.Improve the energy efficiency of heating and cooling to achieve energy saving.


7. Heat Exchanger

High performance shell and tube condenser evaporator has simple structure, large gap, dense copper tube, not easy to scale, strong durability and reasonable matching.


8. Electronic expansion valve

Electronic expansion valves provide precise throttling, decompression and flow regulation Quantity, so that the unit to achieve reasonable The state of equilibrium.


9. Precision distribution box

The wiring is neat and the work is regular to ensure the stable operation of the unit and the line is clear and easy to maintain and operate in the future.


10. Precision welding process

Precision + regular welding process, all marking after the leak, check the leak.


Full range of hot water solutions. Hot water for the whole family in one go.




ModelKCL-05RLKCL-10RLKCL-15RLKCL-25RLKCL-50RL
Refrigeration capacity(kW)13.52734.560120
Heating capacity(kW)(kW)18.436.846.280161.2
Input power(kW)4.99.811.721.441.6
Working Voltage380v/3ph/50Hz380v/3ph/50Hz380v/3ph/50Hz380v/3ph/50Hz380v/3ph/50Hz
Operation controlMicrocomputer automatic control, operating status display, abnormal state alarm
Safety devicesHigh and low voltage switch, anti-freezing swi
tch, overcurrent protection switch, phase sequence protector, compressor overheat protection device
External fan air volume(m³/h)30006000130002000040000
External fan power(kW)0.25(kW)0.5(kW)0.75(kW)1.5(kW)×21.5(kW)×2
Noise(dB)《52《55《56《65《70
Compressor typeScroll typeScroll typeScroll typeScroll typeScroll type
Water-side heat exchangerHigh-efficiency tank/plate exchange typeHigh-efficiency tank type/shell and tube type
Water flow rate(m³/h)68161656
Water-resistance loss167111835
Inlet and outlet pipe diameterDN25DN32DN32DN65DN100
RefrigerantR410A
Number of compressors11114
Working Temperature‘-25℃—45℃
Dimension of the main machine(mm)(mm)1165.5*425.5*12161430*720.5*10691039.5*1039.5*17991039.5*1039.5*19992155*1100*2060
Weight(kg)1453103805102000