Full range of hot water solutions Hot water for the whole family in one go
ECOZ air source heating heat pump is a new type, energy-saving and environment-friendly constant temperature indoor heating system, including three parts: heat source, conveying pipeline and control system. It can provide heating for community houses, apartment buildings, villas, office buildings, hotels, hospitals, public bathrooms, indoor swimming pools and other buildings around the clock.
ECOZ heating heat pump can be used for many purposes in a building. It can be directly connected to various terminals, including fan coil, radiator, floor heating, etc., and it is more flexible to use with it. Apart from heating and cooling, ECOZ heat pump can also be connected to the hot water system in the building, realizing the integration of 24-hour hot water, cooling in summer and heating in winter.
Low temperature air source heat pump heat fan using carpet heating, heating faster, more comfortable so that the warmth fills the corner of the home, in the door of the instant warmth can be oncoming.
Variable frequency compressor is efficient, energy saving, stable and durable
The air conditioner uses a frequency conversion compressor and matches outdoor fans to build DC frequency conversion technology. Compared with ordinary fixed frequency air conditioners, it has the technical advantages of quieter, more energy saving and more stable. The use of air jet enthalpy compressor, low temperature operation performance is better.
-35°C~+45 °C wide temperature operation end can be connected to the floor heating, radiator, fan coil, etc., a variety of combinations free.
ECOZ Eisio air can give you more comfortable warmth
1. The unit is equipped with intelligent defrost function and intelligent induction automatic defrosting, which effectively solves the situation that the unit cannot start due to cold frosting.
2. The use of high-quality spare parts effectively reduces the probability of frost formation and ensures the smooth operation of the unit in cold environments.
3. Microcomputer automatic control,double automatic control, automatic circulation heating, not subject to weather conditions, can run every day all year round, no need for personal care.
4. Using environmentally friendly refrigerant, driven by only a small amount of electrical energy, low energy consumption, no pollutant emissions during the operation of the heat pump unit.
ECOZ EEO variable frequency heating series air energy water heater, minus 35 degrees strong heating, the use of internationally renowned brand heat pump special compressor, unique flash + jet enthalpy technology, R404A environmental refrigerant, electronic expansion valve throttling, intelligent automatic control system defrost, can be in the ambient temperature -35°C strong heating, Widely used in heating, refrigeration, hot water one machine multi-purpose, choose ECOZ Yisi Ou air energy heat pump is equal to choose affordable, affordable price, quality service, can let you in the pre-sale, sale, after-sales and so on the whole worry.
Model | KCL-05RL | KCL-10RL | KCL-15RL | KCL-25RL | KCL-50RL |
Refrigeration capacity(kW) | 13.5 | 27 | 34.5 | 60 | 120 |
Heating capacity(kW)(kW) | 18.4 | 36.8 | 46.2 | 80 | 161.2 |
Input power(kW) | 4.9 | 9.8 | 11.7 | 21.4 | 41.6 |
Working Voltage | 380v/3ph/50Hz | 380v/3ph/50Hz | 380v/3ph/50Hz | 380v/3ph/50Hz | 380v/3ph/50Hz |
Operation control | Microcomputer automatic control, operating status display, abnormal state alarm | ||||
Safety devices | High and low voltage switch, anti-freezing swi tch, overcurrent protection switch, phase sequence protector, compressor overheat protection device | ||||
External fan air volume(m³/h) | 3000 | 6000 | 13000 | 20000 | 40000 |
External fan power(kW) | 0.25(kW) | 0.5(kW) | 0.75(kW) | 1.5(kW)×2 | 1.5(kW)×2 |
Noise(dB) | 《52 | 《55 | 《56 | 《65 | 《70 |
Compressor type | Scroll type | Scroll type | Scroll type | Scroll type | Scroll type |
Water-side heat exchanger | High-efficiency tank/plate exchange type | High-efficiency tank type/shell and tube type | |||
Water flow rate(m³/h) | 6 | 8 | 16 | 16 | 56 |
Water-resistance loss | 16 | 7 | 11 | 18 | 35 |
Inlet and outlet pipe diameter | DN25 | DN32 | DN32 | DN65 | DN100 |
Refrigerant | R410A | ||||
Number of compressors | 1 | 1 | 1 | 1 | 4 |
Working Temperature | ‘-25℃—45℃ | ||||
Dimension of the main machine(mm)(mm) | 1165.5*425.5*1216 | 1430*720.5*1069 | 1039.5*1039.5*1799 | 1039.5*1039.5*1999 | 2155*1100*2060 |