Guangzhou Yike New Energy Technology Co., Ltd. was founded in 2011, is a research and development, independent innovation, production, sales as one of the modern science and technology enterprises, has been committed to manufacturing and sales of heat pump drying dehumidifier, central air conditioning, heat pump water heater and other products.
Through years of research and development and practical experience, the core products of heat pump drying dehumidifier have formed five series of heat pump drying dehumidifier: (1) wood drying special heat pump drying dehumidifier. (2), agricultural products special heat pump drying dehumidifier. (3) Seafood, fish special heat pump drying dehumidifier. (4) Special heat pump drying and dehumidifying machine for production line. (5) Chinese herbal medicine special heat pump drying dehumidifier. The products are sold all over the country and are well received by new and old customers at home and abroad.
Air source heat pump is a kind of energy-saving device that can make the heat flow from the low heat source air to the high heat source. It is a form of heat pump. As the name suggests, the heat pump is like a pump, which can convert the low heat energy that can not be directly used into the high heat energy that can be used, so as to achieve the purpose of saving part of the high energy.
ECOZ uses advanced air energy heat pump technology, which saves 75% energy than ordinary water heaters, 6 to produce the same hot water, which is more energy saving than ordinary electric water heaters, and the annual average energy efficiency ratio is several times that of electric heating, and energy utilization efficiency is high.
ECOZ air source heating heat pump is a new type, energy-saving and environment-friendly constant temperature indoor heating system, including three parts: heat source, conveying pipeline and control system.
For all walks of life heating + hot water
Office buildings, large shopping malls, libraries, agricultural greenhouses heating & refrigeration Central air conditioning series Schools, hospitals, hotel clubs, villas, residential buildings & refrigeration, heating, hot water heat pump series bath center, constant temperature swimming pool, hair salon, district central heating, food processing, commercial hot water series animal husbandry, agricultural aquaculture, aquaculture。
ECOZ heating heat pump can be used for many purposes in a building. It can be directly connected to various terminals, including fan coil, radiator, floor heating, etc., and it is more flexible to use with it. Apart from heating and cooling, ECOZ heat pump can also be connected to the hot water system in the building, realizing the integration of 24-hour hot water, cooling in summer and heating in winter.
1. The unit is equipped with intelligent defrost function and intelligent induction automatic defrosting, which effectively solves the situation that the unit cannot start due to cold frosting.
2. The use of high-quality spare parts effectively reduces the probability of frost formation and ensures the smooth operation of the unit in cold environments.
3. Microcomputer automatic control,double automatic control, automatic circulation heating, not subject to weather conditions, can run every day all year round, no need for personal care.
4. Using environmentally friendly refrigerant, driven by only a small amount of electrical energy, low energy consumption, no pollutant emissions during the operation of the heat pump unit.
5. Intelligent low temperature heat pump to achieve cold winter heating is not limited by low temperature building durable, long life.
6. Heating + cooling double jet enthalpy double jet enthalpy technology.Improve the energy efficiency of heating and cooling to achieve energy saving.
7. Heat Exchanger
High performance shell and tube condenser evaporator has simple structure, large gap, dense copper tube, not easy to scale, strong durability and reasonable matching.
8. Electronic expansion valve
Electronic expansion valves provide precise throttling, decompression and flow regulation Quantity, so that the unit to achieve reasonable The state of equilibrium.
ECOZ has a complete product line, production workshop. Strong technical force, complete production equipment, complete testing means.
In the "cooperation, win-win" business and management philosophy, to achieve excellence, continuous innovation, to serve the majority of customers.
Model | KCL-05RL | KCL-10RL | KCL-15RL | KCL-25RL |
Refrigeration capacity(kW) | 13.5 | 27 | 34.5 | 60 |
Heating capacity(kW)(kW) | 18.4 | 36.8 | 46.2 | 80 |
Input power(kW) | 4.9 | 9.8 | 11.7 | 21.4 |
Working Voltage | 380v/3ph/50Hz | 380v/3ph/50Hz | 380v/3ph/50Hz | 380v/3ph/50Hz |
Operation control | Microcomputer automatic control, operating status display, abnormal state alarm | |||
Safety devices | High and low voltage switch, anti-freezing swi tch, overcurrent protection switch, phase sequence protector, compressor overheat protection device | |||
External fan air volume(m³/h) | 3000 | 6000 | 13000 | 20000 |
External fan power(kW) | 0.25(kW) | 0.5(kW) | 0.75(kW) | 1.5(kW)×2 |
Noise(dB) | 《52 | 《55 | 《56 | 《65 |
Compressor type | Scroll type | Scroll type | Scroll type | Scroll type |
Water-side heat exchanger | High-efficiency tank/plate exchange type | |||
Water flow rate(m³/h) | 6 | 8 | 16 | 16 |
Water-resistance loss | 16 | 7 | 11 | 18 |
Inlet and outlet pipe diameter | DN25 | DN32 | DN32 | DN65 |
Refrigerant | R410A | |||
Number of compressors | 1 | 1 | 1 | 1 |
Working Temperature | ‘-25℃—45℃ | |||
Dimension of the main machine(mm)(mm) | 1165.5*425.5*1216 | 1430*720.5*1069 | 1039.5*1039.5*1799 | 1039.5*1039.5*1999 |
Weight(kg) | 145 | 310 | 380 | 510 |